Biosensor & biochip surfaces (K. Gajos, A. Budkowski et al.)

We examine biomolecular multi-component nanolayers (DNA, protein) serving as biosensor surfaces to optimize bio-functionalization & enhance assay sensitivity. This issue is relevant e.g. for the biochips detecting human diseases and food contamination.

Biosensor surfaces

Biosensors transduce information about amount of chemical substances, analytes, into signals that can be recorded. We participate in multidisciplinary projects targeting various analytes, such as cancer markers and gene mutations, relevant for early diagnosis of human diseases (PYTHIA EU project) or allergens, mycotoxins and pesticides, relevant for food safety (FOODSNIFFER EU project). Our research is focused on biosensor surfaces, where molecular recognition of analytes takes place, a process that lies at the heart of biosensing function. In parallel, we investigate model biosensor systems to develop methodologies for studying biofunctionalization processes and to understand the physical phenomena that influence the structure and properties of biorecognition layers. We apply complementary surface science techniques (e.g. AFM, TOF-SIMS, ellipsometry, XPS) supplemented with biochemical assays1. Over past decade we have developed various appropriate surface analysis methodologies:

  • Optimizing bioreceptor immobilization at biosensor surface using physical adsorption2-5, covalent bonding3-7, specific binding8;
  • Determining surface amounts of all different molecules applied in multi-step and multi-component protocols4,9;        
Fig.1. Composition analysis of biomolecular layers on the sensor surface. Application of the surface analysis (TOF-SIMS and ellipsometry) enables a more accurate evaluation of molecules binding ratio compare to sensor response analysis as well as molecules orientation examination.
  • Evaluating biding stoichiometry more accurately than from biosensor response10; 
  • Determining directly orientation of bioreceptor (e.g. antibody2,3,5-7,9) for different immobilization protocols and in multi-component assays.
Fig.2. Surface density dependent analysis of IgG antibody orientation for molecules immobilized on silicon substrates modified with APTES and APTES/GA.
  • Analysis of bioreceptor immobilization on complex macromolecular surfaces (e.g. lipid layers, polymer brushes).2,6

Biochip surfaces

Since classical analytical technologies are expensive and time consuming, as bound to laboratories, high hopes are placed on cost-effective microarrays of miniaturized biosensors. Such label-free opto-electronic biochips (e.g. PHYTIA or FOODSNIFFER) enable rapid and synchronous multi-analyte detection with a single chip. Therefore, precise spatially resolved immobilization of bioreceptors on respective miniaturized biosensors is highly demanded. For this purpose, we analyse biochip surfaces following bioprinting with a robotic microarray spotter. This has resulted in:

  • Characterization of fast and effective bioprinting of nanolitre droplets of bioreceptors resulting in surface amount twice higher than those of classically pipetted microlitre drops (hand macro-spotting)11;
  • Comparison of different protocols to form DNA arrays based on biotin – streptavidin system, including imaging of bioreceptor distribution within single microarray spots, resulting in the most effective procedure for gene mutation detection8;
Fig.3. TOF-SIMS imaging of DNA spots resulted from different preparation protocols applying biotin-streptavidin system.
  • Conditions, established for uniform bioreceptor immobilization within arbitrary patterns, that boost considerably (5-fold) assay detection sensitivity12;
Fig.4. TOF-SIMS examination of bio-printed protein patterns (I) on opto-electronic biochip (II). Application of optimal bioreceptor immobilization conditions significantly improves sensor sensitivity (III).
  • Optimized bioprinting onto photolithographic micropatterns results in selective immobilization with sub-micrometer spatial resolution13, suitable for the first all-silicon spectroscopic lab-on-chip.
Fig.5. Evaluation of the spatially selective bioreceptor immobilization method, based on APTES layer micropatterning by photolithography and plasma treatment, developed for on-chip interferometric biosensors.

Our research is performed in the frame of different projects:

  • Analysis of antibodies orientation on biosensing surfaces modifed with molecular and macromolecular layers using secondary ion mass spectrometry (NCN UMO-2021/43/D/ST5/02231)
  • Silicon biosensing surfaces functionalization with many molecules: direct analysis of antibody orientation and antigen binding efficiency with secondary ion mass spectroscopy (NCN UMO-2016/21/N/ST5/00880)
  • Foodsniffer: FOOD Safety at the point-of-Need via monolithic spectroscopic chip identIFying harmFul substances in frEsh pRoduce (FP7-ICT8-318319 & 3132/7.PR/2014/2)
  • Protein immobilisation to film surfaces and micro-patterns of conjugated polymer in the aspect of biosensors applications (NCN UMO-2011/03/N/ST5/04764)
  • PYTHIA: Monolithically integrated interferometric biochiPs for label-free earlY deTection of Human dIseAses (FP7-ICT2-224030 & 1460/7. PR UE/2010/7)
     

References

  1. "A perspective on ToF-SIMS analysis of biosensor interfaces: Controlling and optimizing multi-molecular composition, immobilization through bioprinting, molecular orientation" K. Gajos, A. Budkowski, P. Petrou, S. Kakabakos, Applied Surface Science 594 (2022) 153439
  2. "Antibody immobilization and immunorecognition on sphingomyelin and sphingomyelin/cholesterol Langmuir–Blodgett monolayers on silicon: a ToF-SIMS and On-Chip WLRS study", K. Zwolenik, A. Wnȩtrzak, N. Janiszewska, A. Budkowski, K. Gajos, Applied Surface Science 753 (2027) 168377
  3. "​​​​​​​pH-dependent orientation of physisorbed and chemisorbed antibodies on silicon determined with TOF-SIMS and its effect on in-flow capture assay monitored with WLRS sensor" K .Gajos, K. Sanocka, M. Wytrwał, P. Dąbczyński, A. Budkowski, Applied Surface Science 656 (2024) 159644
  4. "​​​​​​​Covalent and Non-covalent In-Flow Biofunctionalization for Capture Assays on Silicon Chips: White Light Reflectance Spectroscopy Immunosensor Combined with TOF-SIMS Resolves Immobilization Stability and Binding Stoichiometry" K. Gajos, A. Orzech, K. Sanocka, P. Petrou, A. Budkowski, Langmuir 39 (2023) 10216-10229
  5. "​​​​​​​Comparison of Physical Adsorption and Covalent Coupling Methods for Surface Density‐Dependent Orientation of Antibody on Silicon" K. Gajos, P. Petrou, A. Budkowski, Molecules 27 (2022) 3672 
  6. "Integrating Protein Resistance and Bioconjugation in P(OEGMA-co-MAA) Brushes for Biosensing and Cell Culture: ToF-SIMS Profiling and Antibody Characterization" K. Gajos, O. Lishchynskyi, P. Dąbczyński, S. Tymetska, Ł. Bodek, Y. Shymborska, N. Janiszewska, Y. Stetsyshyn, A. Budkowski, ACS Applied Materials and Interfaces 18 (2026) 3122-3139
  7. "Surface density dependent orientation and immunological recognition of antibody on silicon: TOF-SIMS and surface analysis of two covalent immobilization methods" K. Gajos, K. Szafraniec, P. Petrou, A. Budkowski, Applied Surface Science 518 (2020), 146269
  8. "Imaging and spectroscopic comparison of multi-step methods to form DNA arrays based on the biotin-streptavidin system" K. Gajos, P. Petrou, A. Budkowski, K. Awsiuk, A. Bernasik, K. Misiakos, J. Rysz, I. Raptis, S. Kakabakos, Analyst 140 (2015), 1127–1139
  9. "Indirect immunoassay on functionalized silicon surface: Molecular arrangement, composition and orientation examined step-by-step with multi-technique and multivariate analysis” K. Gajos, A. Budkowski, V. Pagkali, P. Petrou, M. Biernat, K. Awsiuk, J. Rysz, A. Bernasik, K. Misiakos, I. Raptis, S. Kakabakos, Colloids and Surfaces B: Biointerfaces 150 (2017), 437-444
  10. "Protein adsorption/desorption and antibody binding stoichiometry on silicon interferometric biosensors examined with TOF-SIMS" K. Gajos, A. Budkowski, P. Petrou, V. Pagkali, K. Awsiuk, J. Rysz, A. Bernasik, K. Misiakos, I. Raptis, S. Kakabakos, Applied Surface Science 444 (2018), 187-196
  11. "Contact pin-printing of albumin-fungicide conjugate for silicon nitride-based sensors biofunctionalization: Multi-technique surface analysis for optimum immunoassay performance" K. Gajos, A. Budkowski, Z. Tsialla, P. Petrou, K. Awsiuk, P. Dąbczyński, A. Bernasik, J. Rysz, K. Misiakos, I. Raptis, S. Kakabakos, Applied Surface Science 410 (2017), 79-86
  12. "Imaging and chemical surface analysis of biomolecular functionalization of monolithically integrated on silicon Mach-Zehnder interferometric immunosensors" K. Gajos, M. Angelopoulou, P. Petrou, K. Awsiuk, S. Kakabakos, W. Haasnoot, A. Bernasik, J. Rysz, M. M. Marzec, K. Misiakos, I. Raptis, A. Budkowski, Applied Surface Science 385 (2016), 529-542
  13. "Spatially selective biomolecules immobilization on silicon nitride waveguides through contact printing onto plasma treated photolithographic micropattern: Step-by-step analysis with TOF-SIMS chemical imaging" K. Gajos, A. Budkowski, P. Petrou, K. Awsiuk, K. Misiakos, I. Raptis, S. Kakabakos, Applied Surface Science 506 (2020), 145002

Contact

  • Dr hab. Katarzyna Gajos
  • Prof. dr hab. Andrzej Budkowski